更多

供应


智慧城市网供应网 储备数据 储备设备 其他储备设备S1DXM-A/M多量程定时器

S1DXM-A/M多量程定时器

  • 产地
  • 所在地
  • 暂无
  • 暂无

更新时间:2024-03-28

有效日期:还剩62

产品详情

RoHS規格 UL C-UL Recognaized CE Marking

UL/C-UL , CE Approved

Features

1.Multiple functions built in

The operation mode and time range can be switched by using the MODE and RANGE switches on the front panel.

2.Part number consolidation

1.The lineup consists of 64 easy-to-choosemodels.
2.An operation mode fixed type (S1DXM-A) and 4-operation mode switching type (S1DXM-M) are available.

3.Cadmium-free contacts used

To eliminate environmentally harmful chemical substances, relays with cadmium-free contacts are used.

4.Economically priced

1.Prices set to lower costs.
2.Further cost reduction when used with HJ Relay terminal socket.

5.CE marking supporte

UL and C-UL approved.


Operation Mode


1.S1DXM-A multi-range timer


Operation mode
Power ON-delay operation When power is turned on, the output contact operates after the set time.
The output contact remains on until the power is turned off.


2.S1DXM-M multi-range timer


Operation mode
Power ON-delay operation
[MODE] switch 1: OFF, switch 2: OFF
. When power is turned on, the output contact operates after the set time.
The output contact remains on until the power is turned off.
Power Flicker OFF start operation
[MODE] switch 1: OFF, switch 2: ON
When the power is turned on, the output contacts repeatedly operate at the set time.
The output contact begins from the off state.
Power Flicker ON start operation
[MODE] switch 1: ON, switch 2: OFF
When power is turned on, the output contact operates repeatedly at the set time.
The output contact outputs at the same time power turns on.
Power One-shot operation
[MODE] switch 1: ON, switch 2: ON
When power is turned on, the output contact performs the on operation at the same time power turns on, only for the set time.


Time range setting


Type Time scale Time unit Min.scale Max.scale Setting range
S1DXM-A 10M type ×1 ×10 s m 0.05 1 0.05 to 1s 0.5 to 10s 0.05 to 1m 0.5 to 10m
30M type s m 0.2 3 0.2 to 3s 2 to 30s 0.2 to 3m 2 to 30m
60M type s m 0.5 6 0.5 to 6s 5 to 60s 0.5 to 6m 5 to 60m
10H type m h 0.05 1 0.05 to 1m 0.5 to 10m 0.05 to 1h 0.5 to 10h
S1DXM-M 10M type ×1 ×10 s m 0.05 1 0.05 to 1s 0.5 to 10s 0.05 to 1m 0.5 to 10m
30M type s m 0.2 3 0.2 to 3s 2 to 30s 0.2 to 3m 2 to 30m
60M type s m 0.5 6 0.5 to 6s 5 to 60s 0.5 to 6m 5 to 60m
10H type m h 0.05 1 0.05 to 1m 0.5 to 10m 0.05 to 1h 0.5 to 10h
* The time setting range is the combination of the time scale (X1 or X10) on the dial and the time unit (s, m, or h).
Example: When dial reads 1,time scale is X1 and time units is seconds, then it is 1 second.

Operation Mode and Time Range Setting

Operation mode Power ON-delay Power Flicker OFF start Power Flicker ON start Power One-shot
Operation mode switch
Time range switch
The time setting can be switched among 4 ranges each for 4 types
for an interval between 0.05 seconds and 10 hours.
1* The product is factory shipped with all settings on the OFF side (left).
2* Do not operate the switches with a sharp-edged object such as a knife blade.
3* The power must be turned off when setting the time range or operation mode. Operating the switches with the power on is a cause of breakdown and malfunction.
4* Use a force of under 5 N to operate the DIP switches when setting the time range and operation mode.

Return to top

Part Number

1.S1DXM-A Multi-range Timer
No MODE Switch, Operation Mode (Fixed): Power ON-delay

Operating voltage Time range Timed-out 2 Form C Timed-out 4 Form C
Part Number Part Number
12V DC 0.05s to 10 min S1DXM-A2C10M-DC12V S1DXM-A4C10M-DC12V
0.2 s to 30 min S1DXM-A2C30M-DC12V S1DXM-A4C30M-DC12V
0.5 s to 60 min S1DXM-A2C60M-DC12V S1DXM-A4C60M-DC12V
0.05 min to 10 hr S1DXM-A2C10H-DC12V S1DXM-A4C10H-DC12V
24V DC 0.05 s to 10 min S1DXM-A2C10M-DC24V S1DXM-A4C10M-DC24V
0.2 s to 30 min S1DXM-A2C30M-DC24V S1DXM-A4C30M-DC24V
0.5 s to 60 min S1DXM-A2C60M-DC24V S1DXM-A4C60M-DC24V
0.05 min to 10 hr S1DXM-A2C10H-DC24V S1DXM-A4C10H-DC24V
100 to 120V AC 0.05 s to 10 min S1DXM-A2C10M-AC120V S1DXM-A4C10M-AC120V
0.2 s to 30 min S1DXM-A2C30M-AC120V S1DXM-A4C30M-AC120V
0.5 s to 60 min S1DXM-A2C60M-AC120V S1DXM-A4C60M-AC120V
0.05 min to 10 hr S1DXM-A2C10H-AC120V S1DXM-A4C10H-AC120V
200 to 220V AC 0.05 s to 10 min S1DXM-A2C10M-AC220V S1DXM-A4C10M-AC220V
0.2 s to 30 min S1DXM-A2C30M-AC220V S1DXM-A4C30M-AC220V
0.5 s to 60 min S1DXM-A2C60M-AC220V S1DXM-A4C60M-AC220V
0.05 min to 10 hr S1DXM-A2C10H-AC220V S1DXM-A4C10H-AC220V

2.S1DXM-M Multi-range Timer
With MODE Switch, Operation Mode (Switchable): Power ON-delay, Power Flicker ON Start, Power Flicker OFF Start, Power One-shot

Operating voltage Time range Timed-out 2 Form C Timed-out 4 Form C
Part Number Part Number
12V DC 0.05 s to 10 min S1DXM-M2C10M-DC12V S1DXM-M4C10M-DC12V
0.2 s to 30 min S1DXM-M2C30M-DC12V S1DXM-M4C30M-DC12V
0.5 s to 60 min S1DXM-M2C60M-DC12V S1DXM-M4C60M-DC12V
0.05 min to 10 hr S1DXM-M2C10H-DC12V S1DXM-M4C10H-DC12V
24V DC 0.05 s to 10 min S1DXM-M2C10M-DC24V S1DXM-M4C10M-DC24V
0.2 s to 30 min S1DXM-M2C30M-DC24V S1DXM-M4C30M-DC24V
0.5 s to 60 min S1DXM-M2C60M-DC24V S1DXM-M4C60M-DC24V
0.05 min to 10 hr S1DXM-M2C10H-DC24V S1DXM-M4C10H-DC24V
100 to 120V AC 0.05 s to 10 min S1DXM-M2C10M-AC120V S1DXM-M4C10M-AC120V
0.2 s to 30 min S1DXM-M2C30M-AC120V S1DXM-M4C30M-AC120V
0.5 s to 60 min S1DXM-M2C60M-AC120V S1DXM-M4C60M-AC120V
0.05 min to 10 hr S1DXM-M2C10H-AC120V S1DXM-M4C10H-AC120V
200 to 220V AC 0.05 s to 10 min S1DXM-M2C10M-AC220V S1DXM-M4C10M-AC220V
0.2 s to 30 min S1DXM-M2C30M-AC220V S1DXM-M4C30M-AC220V
0.5 s to 60 min S1DXM-M2C60M-AC220V S1DXM-M4C60M-AC220V
0.05 min to 10 hr S1DXM-M2C10H-AC220V S1DXM-M4C10H-AC220V

Return to top

Option

S1DXM-A/M/S1DX Common Options

  • Accesories(mm inch)
  • Socket leaf holding clip for S1DX
  • Terminal socket
  • mm
    inch

Accesories

Mounting frame

ADX18002 / ADX18002 (Titanium-gray) / ADX18006 (Gray) / ADX18007 (Black)

Appearance
Panel cutout dimensions
Board thickness 1 to 3 mm
Note)Make sure the holes area stays as right angles.
Protective cover

ADX18008

Cap block

ADX18011

Cap

ADX18004

Socket

ADX18003

Return to top

Socket Leaf Holding Clip for S1DX

ADX18012 AD68002
Figure Dimensions Figure Dimensions

Socket lime holding clip for S1DXM-A/M

ADX28005
Dimensions
Type Application
Terminal socket ADX18012 AD68002 ADX28005
For HC relay AP3821 - available available
AP3827K - available
AP3847K - available
For HJ relay AHJ3821 available - -
AHJ38211 available - -
AHJ3848 - -
AHJ38481 - -

The triangles indicate that removal will be slightly difficult when installed laterally in succession.

Return to top

Terminal Socket

HC2 slim DIN terminal socket

HC2-SFD-S

HC2 DIN high terminal socket

HC2-SFD-K

HC4 DIN high terminal socket

HC4-SFD-K

HC4 socket

HC4-SS-K

HJ2 terminal socket

HJ2-SFD/HJ2-SFD-S

HJ4 terminal socket

HJ4-SFD/HJ4-SFD-S

HC relay terminal sockets

For general rails
Name / Part No. Terminal socket, HC 2-pin

HC2-SF-K
Dimensions
Note) Only wire springs can be used.(Plate springs cannot be used.)
Terminal layout
Mounting hole dimensions
Panel hole dimensions for side-by-side mounting
Applicable timers S1DX(2c), S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Not Available
Name / Part No. Terminal socket, HC 2-pin

HC4-HSF-K
Dimensions
Note) Only wire springs can be used.(Plate springs cannot be used.)
Terminal layout
Mounting hole dimensions
Panel hole dimensions for side-by-side mounting
Applicable timers S1DX(2c), S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Available
For DIN rails
Name / Part No. Slim DIN terminal socket,HC2

HC2-SFD-S
Dimensions
Terminal layout
Mounting hole dimensions
Applicable timers S1DX(2c), S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Not Available

HJ relay terminal sockets

Name / Part No. HJ2h terminal socket

HJ2-SFD
Dimensions
Terminal layout
Mounting hole dimensions
Applicable timers S1DX(2c),S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Not Available
Name / Part No. HJ2h terminal socket(Finger protect type)

HJ2-SFD-S
Dimensions
Terminal layout
Mounting hole dimensions
Applicable timers S1DX(2c),S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Not Available
Name / Part No. HJ4 terminal socket

HJ4-SFD
Dimensions
Terminal layout
Mounting hole dimensions
Applicable timers S1DX(2c),S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Available
Name / Part No. HJ4 terminal socket(Finger protect type)

HJ4-SFD-S
Dimensions
Terminal layout
Mounting hole dimensions
Drilling size of panel holes for installing the terminal sockets parallel
Applicable timers S1DX(2c),S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Available

Sockets

Name / Part No. Socket HC 2-pin 

HC2-SS-K
Dimensions The difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same.

General tolerance: ±0.5 ±.020
Mounting hole dimensions The thickness of applicable chassis plates ranges from 1.0 to 2.0 mm .039 to .079 inch.
To install the socket easily, insert the socket top surface into the drilled holes and press the two points on the fastening plate indicated by arrows as shown in the fig. below.

Dimensional tolerance of machining: ±0.1 ±.004
Applicable timers S1DX(2c),S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Not Available
Name / Part No. Socket, HC 4-pin 

HC4-SS-K
Dimensions The difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same.

General tolerance: ±0.5 ±.020
Mounting hole dimensions The thickness of applicable chassis plates ranges from 1.0 to 2.0 mm .039 to .079 inch.
To install the socket easily, insert the socket top surface into the drilled holes and press the two points on the fastening plate indicated by arrows as shown in the fig. below.

Dimensional tolerance of machining: ±0.1 ±.004
Applicable timers S1DX(2c),S1DXM(2c) S1DX(4c), S1DXM(4c)
Available Available
*Sockets for PC board
HC2-Socket for PC board: AP3825K
HC4-Socket for PC board: AP3845K

Return to top

Return to top

Dimensions

  • Unit: mm in


  • 1.S1DXM-A
  • 2.S1DXM-M


1.S1DXM-A

General tolerance : ±0.5 ±0.20


Terminal layouts and Wiring diagram
Timed-out 2 Form C type



Terminal layouts and Wiring diagram
Timed-out 4 Form C type


* For the DC operating type, terminal 14 is “+” and terminal 13 is “-”.

2.S1DXM-M

General tolerance : ±0.5 ±0.20


Terminal layouts and Wiring diagram
Timed-out 2 Form C type



Terminal layouts and Wiring diagram
Timed-out 4 Form C type


* For the DC operating type, terminal 14 is “+” and terminal 13 is “-”.

Return to top


免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,智慧城市网对此不承担任何保证责任。

发布询价单

北京科恩众和工业控制技术有

型:
其他
联系人:

联系我时,请说明是在智慧城市网上看到的,谢谢

商家概况

主营产品:
公司性质:
其他

该商家其它产品

数字光纤传感器 FX-300系列 电缆型放大器标准型 FX-301-C1 / FX-301P-C1

数字光纤传感器 F...

摘要:检查性能大幅提升・高功能 [详细]
数字光纤传感器 FX-300系列 连接器型放大器高功能型 FX-305 / FX-305P

数字光纤传感器 F...

摘要:检查性能大幅提升・高功能 [详细]
数字光纤传感器 FX-300系列 连接器型放大器高速型 FX-301-HS / FX-301P-HS

数字光纤传感器 F...

摘要:检查性能大幅提升・高功能 [详细]
支持开放式网络S-LINK V网关控制器

支持开放式网络S-...

摘要:拓展技术可能性新一代的省 [详细]
数字光纤传感器 FX-300系列 连接器型放大器标准型 FX-301H / FX-301HP

数字光纤传感器 F...

摘要:检查性能大幅提升・高功能 [详细]
数字光纤传感器 FX-300系列 连接器型放大器标准型 FX-301G / FX-301GP

数字光纤传感器 F...

摘要:检查性能大幅提升・高功能 [详细]
数字光纤传感器 FX-300系列 连接器型放大器标准型 FX-301B / FX-301BP

数字光纤传感器 F...

摘要:检查性能大幅提升・高功能 [详细]
数字光纤传感器FX-410系列 连接器型放大器FX-412 / FX-412B / FX-412G

数字光纤传感器FX...

摘要:只需查看旋转的简单易操作 [详细]

其它商家同类产品